Test Code VWFAG von Willebrand Factor Antigen

Laboratory Code

LAB5277

Specimen Requirements

Submit only one of the following specimens


Specimen Type: Whole Blood
Container/Tube: 2 Light Blue Top (3.2% Sodium Citrate)
Volume: 2 × 2.7 mL (Tubes must be full)
Collection Instructions: Send whole blood specimens to laboratory immediately.


Specimen Type: Platelet Poor Plasma
Container/Tube: 2 Light Blue Top (3.2% Sodium Citrate)
Submission Container/Tube: Plastic Vial

Minimum Volume: 1.0 mL Plasma
Collection Instructions:
1. Light blue top tube must be properly filled with whole blood.

2. Whole blood specimen should be double centrifuged and plasma separated from cells within 1 hr of collection.
3. Plasma should be separated into 2 aliquots with minimum volume of 1.0 mL each.
4. Freeze the aliquots in well-closed plastic tubes immediately.

Specimen Stability

Specimen Type Plasma
Ambient 4 hours
Refrigerate 4 hours
Frozen 14 days (preferred)

Methodology

Immunoturbidimetric Assay

Days and Times Performed

Friday, TAT 21 days

Specimen Condition

Haemolysis Gross reject
Icterus Gross reject
Lipaemia Gross reject
Others: Clotted or insufficient Reject

Reference Interval

Blood O-group 54 – 148 %
Blood group non-O 72 – 167%

Testing Laboratory

National University Hospital
Haematology, 67725320

Useful For

Aids in the diagnosis of von Willebrand’s Disease.

Service Code

12013

LOINC Code Information

27816-8

Alias

vWF:Ag

vWF

Update