Sign in →

Test Code SGU Specific Gravity, Urine

Specimen Requirements

Specimen Type: Urine
Container/Tube: Urine Cup
Volume: 100mL
Minimum Volume: 20mL
Collection Instructions: Collect mid-stream urine in preservative-free urine container.

Sample Stability

** Preferred temperatures for storage prior to and during shipping to NUH **

 

Specimen Type: Urine
Ambient: 1 day
Refrigerate: 1 week
Frozen: 6 months

 

Reference Interval

1.003 -1.030

 

 

Days and Times Performed

24 hours, TAT 1 day

Methodology

Refractometry

Service Code

31251

Update

Last updated 26/02/2022

Unacceptable Condition

 

Haemolysis NA
Icterus NA
Lipaemic NA
Others NA

 

Testing Laboratory

National University Hospital

Clinical Chemistry, 67724346

Useful For

Assessment of the kidney’s ability to concentrate urine. An aid in determining the type of body fluid: exudate versus transudate.