Sign in →

Test Code RUM Rubella IgM Antibody

Specimen Requirements

Specimen Type: Serum
Container/Tube: Gold Top (SSTII) / Red Top
Volume: 5.0mL / 6.0mL blood
Minimum Volume: 0.5mL serum
Collection Instructions: Allow specimen to clot for 30 minutes and centrifuge within 2 hours

Sample Stability

** Preferred temperatures for storage prior to and during shipping to NUH ** 

 

Specimen Type:  Serum
Ambient:  2 days
Refrigerate:  14 days
Frozen:  1 year 

 

Reference Interval

Non-Reactive

Days and Times Performed

Monday, Wednesday, Friday, TAT 2 – 4 days

Methodology

Chemiluminescent Immunoassay

Service Code

0031854

Update

last updated 16/05/2024

Updated on Methodology.

Unacceptable Condition

Haemolysis:  Gross reject
Icterus: NA
Lipaemic: NA
Others:  NA

 

Testing Laboratory

National University Hospital

Clinical Chemistry, 67724346

Useful For

A “reactive” result suggests current or recent exposure to rubella

Alias

RUBM, Rubella Antibody IgM, Rubella
serology