Sign in →

Test Code MRPPN, MRPPB Respiratory Pathogens Panel PCR

Laboratory Code

MRPPN LAB3053554
MRPPB LAB3053555

 

Specimen Requirements

Preferred
Specimen Type: Nasopharyngeal swab
Container/Tube: Flocked Swab in Universal Transport Medium (UTM)
Volume: 3.0 mL (entire collection)
Collection Instructions: Please collect Flocked swab and UTM from NUH Microbiology Laboratory.

 

Acceptable
Specimen Type: Bronchoalveolar lavage (BAL)

This assay is not validated for this sample matrix. Please interpret the result with caution and correlate with other clinical findings.
Container/Tube: Sterile screw-capped container
Volume: 2.0 mL
Minimum volume: 1.0 mL

Specimen Stability

Specimen Type Nasopharyngeal swab
Ambient As soon as possible, up to 4 hours
Refrigerate Up to 72 hours
Frozen NA. Please contact lab for more information. 

Methodology

Real-time Multiplexed Polymerase Chain Reaction (RT-PCR)

Days and Times Performed

Monday through Sunday, TAT 1 day

Reference Interval

Not detected.

 

Critical Values: Clinician will be informed of SARS-CoV-2, Bordetella pertussis and Bordetella parapertussis positive results, if patient is ≤18 years old.

Testing Laboratory

National University Hospital
Clinical Microbiology, 67724343

Useful For

For the simultaneous qualitative detection and identification of multiple respiratory viral and bacterial nucleic acids obtained from individuals suspected of respiratory tract infections, including COVID-19.

 

Respiratory pathogens tested include:

1. Influenza A (H1, H3, H1-2009)

2. Influenza B

3. Respiratory Syncytial Virus

4. Coronavirus (229E, OC43, NL63, and HKU1)

5. Parainfluenza virus 1, 2, 3, and 4

6. Human metapneumovirus

7. Enterovirus/Rhinovirus

8. Adenovirus

9. SARS-CoV-2

10. Chlamydophila pneumoniae

11. Mycoplasmoides (Mycoplasma) pneumoniae

12. Bordetella parapertussis

13. Bordetella pertussis

Service Code

23619

LOINC Code Information

MRPPN 82159-5
MRPPB Not applicable

Update

Last updated 21/3/2025