Test Code MCRYC, MCRYS Cryptococcal Antigen

Infectious

Specimen Requirements

Submit only one of the following

Specimen Type: Serum
Container/Tube: Red Top / Gold Top (SSTII) 
Volume: 6.0mL, 0.5 mL / 5.0mL
Minimum Volume: 0.5mL serum


Specimen Type: CSF
Container/Tube: Sterile, screw-capped container

Volume: 1.0 - 2.0mL

Minimum Volume: 0.5mL

Sample Stability

Preferred temperatures for storage prior to and during shipping to NUH 

 

Specimen Type:  Serum, CSF
Ambient:  Submit sample to lab immediately
Refrigerate:  72 hours
Frozen:  Do not repeatedly freeze and thaw sample more than twice

 

Reference Interval

Titre < 1

 

Call back value: Requesting clinician/ location will be informed of positive result.

Days and Times Performed

Monday through Sunday, TAT 1 day

Methodology

Lateral flow immunochromatographic assay

Service Code

23134

Update

Last updated 5/6/2024

Unacceptable Condition

Non-sterile CSF may affect test results.

 

Testing Laboratory

National University Hospital
Clinical Microbiology, 67724343

Useful For