Test Code LDLM LDL-Cholesterol, measured
Laboratory Code
LAB102
Specimen Requirements
Submit only one of the following:
Preferred
Specimen Type: Serum
Container/Tube: Gold Top (SSTII)
Volume: 5.0 mL
Minimum Volume: 0.5 mL serum
Collection Instructions: Allow specimen to clot for 30 mins and centrifuge within 2 hrs.
Acceptable
Specimen Type: Plasma
Container/Tube: Green Top (Li Heparin/PST)
Volume: 4.5 mL
Minimum Volume: 0.5 mL plasma
Collection Instructions: Centrifuge within 2 hrs.
Specimen Stability
Specimen Type | Serum |
---|---|
Ambient | Not available |
Refrigerate | 5 days |
Frozen (-80˚C) | 3 months |
Methodology
Enzymatic Assay
Days and Times Performed
24 hrs, TAT 1 day
Specimen Condition
Gross Haemolysis | Alert/Reject |
---|---|
Icterus | OK |
Lipaemia | OK |
Others | Not applicable |
Reference Interval
Interpretation:
Optimal | < 2.6 mmol/L |
---|---|
Desirable | 2.6 – 3.3 mmol/L |
Borderline high | 3.4 – 4.0 mmol/L |
High | 4.1 – 4.8 mmol/L |
Very high | ≥ 4.9 mmol/L |
Testing Laboratory
National University Hospital
Clinical Chemistry, 67724346
Useful For
Risk factor for Coronary Heart Disease (CHD).
Service Code
31165
LOINC Code Information
69419-0
Alias
Low-Density Lipoprotein
Update
Last updated 11/03/2025