Sign in →

Test Code J1213 JAK2 Exons 12 & 13 Mutations Detection

Additional Codes

Epic Ordering Code LAB5241
NBS code LBC07191
Service code 1035074

Specimen Requirements

Submit the following: 

 

Preferred:

Purple Top

Processing Requirements

Specimen type: Whole Blood or Bone Marrow Aspirate

Volume: 3.0 mL (at least 1.0 mL for bone marrow aspirate)

Storage/transport requirements: Ambient or refrigerated

Specimen Stability

Specimen Type Whole Blood or Bone Marrow Aspirate
Ambient 7 days
Refrigerate 7 days

Methodology

Polymerase Chain Reaction, DNA sequencing

Days and Times Performed

TAT 21 - 30 days

Reference Interval

An interpretative report will be provided.

Testing Laboratory

National University Hospital
Genomics Diagnostic Laboratory, 67724384

Useful For

This is a second line test that should be used when the test for JAK2 Val617Phe(V617F) mutation is negative. The test aids in the distinction between a reactive cytosis and a myeloproliferative neoplasm.

Update

Last updated 11/06/2026

Test Info

(a)  This test was developed by NUH Laboratory Medicine.

(b) This laboratory test has undergone in-house evaluation with appropriate quality assurance and control measures in line with laboratory best practice and accreditation requirements.