Sign in →

Test Code Glucose 0, Glucose 60, Glucose 120 Glucose Tolerance Test (3 points)

Laboratory Code

LAB3053029

Specimen Requirements

Specimen Type: Plasma

Container/Tube: Grey Top (Sodium Fluoride/Potassium Oxalate)
Volume: 4.5 mL
Minimum Volume: 0.5 mL plasma
Collection Instructions: Fast patient 10-12 hours before sample collection. Mix specimen well to avoid clotting. Centrifuge within 2 hrs.

Specimen Stability

Specimen Type Plasma (Stabilized with sodium fluoride/potassium oxalate)
Ambient 2 days
Refrigerate 7 days
Frozen 3 months

Methodology

Enzymatic Assay

Days and Times Performed

24 hrs, TAT 1 day

Specimen Condition

Haemolysis OK
Icterus OK
Lipaemia OK
Others Not applicable

Reference Interval

  Non-diabetic Gestational Diabetes Possible pre-existing Diabetes
Fasting 3.0 – 5.0 mmol/L 5.1 – 6.9 mmol/L => 7.0 mmol/L 
60 min ≤ 9.9 mmol/L  => 10.0 mmol/L  
120 min ≤ 8.4 mmol/L   8.5 – 11.0 mmol/L  => 11.1 mmol/L

Testing Laboratory

National University Hospital

Clinical Chemistry, 67724346

Useful For

Diagnosis of gestational diabetes.

Service Code

31200

LOINC Code Information

Glucose 0 min  14768-6
Glucose 60 min  25665-1 
Glucose 120 min  25668-5 

Update