Sign in →

Test Code ENA Anti-extractable Nuclear Antigen Identification

Laboratory Code

LAB5040

Specimen Requirements

Specimen Type: Serum
Container/Tube: Gold Top (SSTII) / Red Top
Volume: 5.0 mL / 6.0 mL blood
Minimum Volume: 0.5 mL serum
Collection Instructions: Allow specimen to clot for 30 mins and centrifuge within 2 hrs

Specimen Stability

Specimen Type Serum
Ambient 2 days
Refrigerate 2 weeks (preferred)
Frozen 1 year

Panel Information

Panel includes the following tests:

  • Anti-JO1 IgG
  • Anti-LA (SSB) IgG
  • Anti-RNP/SM IgG
  • Anti-RO (SSA) IgG
  • Anti-SCI 70 IgG
  • Anti-SM IgG

Methodology

Enzyme Immunoassay

Days and Times Performed

Wednesday, TAT 2 - 8 days

Specimen Condition

Haemolysis OK
Icterus OK
Lipaemia OK
Others Not applicable

Reference Interval

No antibodies detected:  < 1.0

Weak positive: 1.0 – < 2.0

Positive:  2.0 – < 5.0 

Strong positive:  ≥ 5.0

Testing Laboratory

National University Hospital

Clinical Chemistry, 67724346

Useful For

Identifies presence or absence of anti-extractable nuclear antigens

Service Code

32143

LOINC Code Information

Not available

Alias

Anti-ENA (Antibodies to Extractable Nuclear Antigens)

ENAP

Update

Last updated 21/02/2025