Test Code DSGAB Desmoglein 1 (DSG1) and Desmoglein 3 (DSG3), IgG Antibodies, Serum
Additional Codes
| Epic Ordering Code | LAB3040811 |
| NBS code | LBC13182 |
| Service code | 36909 |
Reporting Name
Desmoglein 1 and 3, SerumSpecimen Type
SerumSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL Serum
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
NUH Outreach Laboratories:
Specimen Requirements
Submit only one of the following:
Preferred: Red Top
Acceptable: Yellow Top
Processing Requirements
Centrifuge and aliquot serum into a Mayo plastic tube.
Specimen type: Serum
Volume: 1 mL
Storage/transport requirements: Refrigerated
Special Instructions
Specimen Minimum Volume
Serum: 0.5 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 14 days |
| Frozen | 30 days | |
| Ambient | 14 days |
Reject Due To
| Gross hemolysis | OK |
| Gross lipemia | OK |
| Gross icterus | OK |
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Testing Algorithm
For information see Autoimmune Blistering Disease Diagnostic Algorithm.
Day(s) Performed
Varies
Report Available
1 to 10 daysPlease note that this is a referral test requiring transport to the external testing facility and an additional 3-5 days is required.
Reference Values
Desmoglein 1:
<20 RU/mL (Negative)
≥20 RU/mL (Positive)
Desmoglein 3:
<20 RU/mL (Negative)
≥20 RU/mL (Positive)
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Useful For
Preferred screening test for patients suspected of having an autoimmune blistering disorder of the skin or mucous membranes (pemphigus)
Aiding in the diagnosis of pemphigus
CPT Code Information
83516 x 2
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| DSGAB | Desmoglein 1 and 3, Serum | 94335-7 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| 606818 | DSG 1 | 94336-5 |
| 606819 | DSG 3 | 94337-3 |
Secondary ID
606818Test Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.Last updated 17/07/2026