Sign in →

Test Code DCPCR Dengue virus and Chikungunya virus RNA PCR

Laboratory Code

LAB3041862 (Blood)

LAB3041347 (Urine)

Specimen Requirements

Specimen Type: Whole Blood
Container/Tube: Lavender Top (EDTA)
Specimen Volume: 3.0 mL


Specimen Type: Urine (Random)
Container/Tube: Sterile Plain Container
Specimen Volume: 10.0 - 15.0 mL

Specimen Stability

48 hours, refrigerated

Methodology

Real-time Reverse Transcription-Polymerase Chain Reaction, Qualitative

Days and Times Performed

Monday, Wednesday, Friday, TAT 1 - 3 days

Specimen Condition

Whole blood: Frozen or hemolysis Reject

 

 

Testing Laboratory

National University Hospital
Molecular Diagnosis Centre, 67724384

Useful For

Detection of Dengue virus and Chikungunya virus RNA

Service Code

1033831

Update

Last updated 20/03/2025

Test Info

(a)  This test was developed by NUH Laboratory Medicine.

(b) This laboratory test has undergone in-house evaluation with appropriate quality assurance and control measures in line with laboratory best practice and accreditation requirements. 