Cystatin C with Estimated Glomerular Filtration Rate (eGFR), Serum
Reporting Name
Cystatin C with Estimated GFR, SFor NUH patients - use Epic to order (LAB3041914)
NUH service code - 37106
Mayo test code - CSTCE
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Serum gel tubes should be centrifuged within 2 hours of collection.
2. Red-top tubes should be centrifuged and serum aliquoted into a plastic vial within 2 hours of collection.
Secondary ID
614154Useful For
Assessing kidney function in patients suspected of having kidney disease
Monitoring treatment response in patients with kidney disease
An index of glomerular filtration rate (GFR), especially in patients where serum creatinine may be misleading (eg, very obese, older adults, or malnourished patients)
Calculation of Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) cystatin C estimated GFR for patients where serum creatinine may be misleading (eg, very obese, older adults, or malnourished patients)
Method Name
Immunoturbidimetric
Specimen Type
SerumSpecimen Minimum Volume
0.25 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 30 days | ||
Ambient | 7 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Gross icterus | Reject |
Reference Values
CYSTATIN C:
18-49 years: 0.63-1.03 mg/L
≥50 years: 0.67-1.21 mg/L
0-17 years: Reference values have not been established. Refer to estimated glomerular filtration rate (eGFR).
ESTIMATED GFR:
>60 mL/min/BSA (body surface area)
Adult eGFR: Estimated GFR calculated using CKD-EPI Cystatin C equation.(1)
Pediatric eGFR: Estimated GFR calculated using Schwartz Cystatin C equation.(12)
Day(s) Performed
Report Available
Same day/1 to 3 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
82610
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
CSTCE | Cystatin C with Estimated GFR, S | 87430-5 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
GFRC | eGFR by Cystatin C | 50210-4 |
CSTNC | Cystatin C, S | 33863-2 |
Forms
If not ordering electronically, complete, print, and send one of the following forms with the specimen:
-General Test Request (T239)
-Cardiovascular Test Request Form (T724)
-Renal Diagnostics Test Request (T830)
Updated on 21/03/2022