Test Code CGB Cryoglobulin Screen
Laboratory Code
LAB4000
Specimen Requirements
Specimen Type: Serum
Container/Tube: Red Top
Volume: 6.0 mL
Collection Instructions: Collect blood in pre-warmed tube and keep at 37°C. To call BTS at 6772 2305 to arrange for 37°C transport container to ensure sample is kept at 37°C before reaching the lab.
Send specimen to the Laboratory immediately. Transport container cannot be sent via pneumatic tube, please arrange for samples to be sent to lab by hand once collected.
Specimen Stability
Specimen Type | Serum |
---|---|
Ambient | Not Applicable |
At 37°C | Freshly drawn samples (preferred) |
Refrigerate | Not Applicable |
Frozen | Not Applicable |
Methodology
Precipitation of Cryoglobulin at 4°C
Days and Times Performed
Monday through Sunday
Routine, TAT 1 day
Specimen Condition
Gross Haemloysis | Reject |
---|---|
Icterus | OK |
Lipaemia | OK |
Others | Insufficient specimen, Kept in ice/refrigerated, NUH patients - sample not sent using the 37°C transport container - Reject |
Reference Interval
Negative
Testing Laboratory
National University Hospital
Transfusion Services, 67722305
Useful For
Screen for presence of abnormal globulins in conditions such as Systemic Lupus Erythematosus, myeloma & lymphoma
Service Code
2012203
LOINC Code Information
LAB4000
Update
Last updated 16/06/2025