Test Code CGB Cryoglobulin Screen

Important Note

For external clients

Please ensure that sample is clotted at 37°C and serum is separated at 37°C. Please provide primary collection tube. 

Specimen Requirements

Specimen Type: Serum
Container/Tube: Red Top

Volume: 6.4mL
Collection Instructions: Collect blood in pre-warmed tube and keep at 37°C.

Send specimen to the Laboratory immediately.

Reference Interval

Negative

Days and Times Performed

24 hours, TAT 1 week

Methodology

Precipitation of Cryoglobulin at 4°C

Service Code

2012203

Update

Last updated 03/04/2023

Unacceptable Condition

 

Haemolysis NA
Icterus NA
Lipaemic NA
Others

Sample kept refrigerated prior

to testing will be rejected.

 

Specimen Stability

Keep sample warm at 37°C and send to Blood Bank immediately after collection

Testing Laboratory

National University Hospital
Transfusion Services, 67722305

Useful For

Screen for presence of abnormal globulins in conditions such as systemic lupus erythematosus, myeloma & lymphoma