Test Code CCSC2 Cyclosporin, C2
Specimen Requirements
Specimen Type: Whole blood
Container/Tube: Purple Top (EDTA)
Volume: 3.0mL
Minimum Volume: 3.0mL
Collection Instructions: Mix sample well to avoid clotting. Collect sample within an hour before the next dose, except patients on continuous infusion.
Sample Stability
** Preferred temperatures for storage prior to and during shipping to NUH **
Specimen Type: | Whole Blood |
---|---|
Ambient: | Send the sample to the laboratory immediately. |
Refrigerate: | 7 days |
Reference Interval
Whole blood levels
Kidney <6 mths | 250 - 375 ug/L |
---|---|
Kidney >6 mths | 100 - 200 ug/L |
Liver <1 mth | 300 - 450 ug/L |
Liver 2-6 mths | 250 - 350 ug/L |
Liver >6 mths | 150 - 250 ug/L |
Bone Marrow | 150 - 250 ug/L |
Cardiac <6 wks | 300 - 420 ug/L |
Cardiac 6-12 wks | 180 - 300 ug/L |
Cardiac >12 wks | 120 - 180 ug/L |
Days and Times Performed
24 hours, TAT 1 day
Methodology
Chemiluminescent Microparticle Immunoassay (CMIA)
Service Code
31820
Update
Last updated 22/08/2022
Unacceptable Condition
Haemolysis | NA |
---|---|
Icterus | NA |
Lipaemic | NA |
Others | Non-EDTA, Clotted sample |
Testing Laboratory
National University Hospital
Clinical Chemistry, 67724346
Useful For
Monitoring anti rejection therapy. Dose adjustment to optimize immunosuppression while minimizing toxicity.