Sign in →

Test Code AMH Antimullerian Hormone

Laboratory Code

LAB1733

Specimen Requirements

Specimen Type: Serum
Container/Tube: Red Top (Plain)
Volume: 6.0 mL
Minimum Volume: 0.5 mL serum
Collection Instructions: Allow specimen to clot for 30 mins and centrifuge within 2 hrs.

Specimen Stability

Specimen Type Serum
Ambient 3 days
Refrigerate 5 days
Frozen 6 months

Methodology

Electrochemiluminescent Immunoassay

Days and Times Performed

Monday through Friday, TAT 4 days

Specimen Condition

Haemolysis OK
Icterus OK
Gross Lipaemia Alert/Reject
Others Not applicable

Reference Interval

Age Male Female
  5.5 – 103.0 pmol/L -
20 – 24 - 8.7 – 83.6 pmol/L
25 – 29 - 6.4 – 70.3 pmol/L
30 – 34 - 4.1 – 58.0 pmol/L
35 – 39 - 1.1 – 53.5 pmol/L
40 – 44 - 0.2 – 39.1 pmol/L
45 – 50 - 0.1 – 19.3 pmol/L

 

 

 

 

 

 

 

 

 

Testing Laboratory

National University Hospital

Clinical Chemistry, 67724346

Useful For

A marker for ovarian reserve.

Assessment of menopausal status e.g. in premature ovarian failure.

Assessment of ovarian function in patients with polycystic ovarian syndrome.

Service Code

31673

LOINC Code Information

83105-7

Alias

Mullerian inhibiting factor (MIF)

Mullerian-inhibiting hormone (MIH)

Update