Test Code ABID Antibody Identification (Red Cell)

Specimen Requirements

Submit 2 full tubes from one of the following
 

Preferred
Specimen Type: Clotted Blood
Container/Tube: Red Top
Volume: 6.4mL

Collection Instructions: Submit 2 full tubes.

Acceptable
Specimen Type: EDTA
Container/Tube: Pink Top
Volume: 6.0mL

Collection Instructions: Submit 2 full tubes.
 

Days and Times Performed

24 hours, TAT 1 day

Methodology

Immune Agglutination

Service Code

2012206

Update

Last updated 02/03/2016

Unacceptable Condition

Haemolysis Gross invalidate result
Icterus NA
Lipaemia NA
Others

Insufficient sample will

be rejected

 

Specimen Stability

Samples are kept for 14 days. Test best performed on fresh drawn samples

Testing Laboratory

National University Hospital
Transfusion Services, 67722305

Useful For

Determine the specificity of antibody/antibodies detected during antibody screening

Reflex Testing

Direct Antiglobulin (Coomb’s) Test
Antibody Titre, Others
Red Cell Phenotyping